NF F 16-101/102 French rail transit vehicle materials flame retardant and fireproof
NF F 16-101/102 Test item Test name : Railway Rolling Stock Fire Behavior Choice of Material French rail transit vehicle material flame retardant and fire protection
NF F 16-101/102 Test info Test content:
1) Reaction to fire fire reflection grade M0-M4
NF P 92-503
8pcs
of 600mm x 180mm x end-use thickness ( not
exceed 5mm )
NF P 92-501
8 pcs
of 300mm x 400mm x end-use thickness ( not
exceed 120mm )
NF P 92-505
8 pcs of 70mm x 70mm x
end-use thickness
NF P 92-504 (special cases subject to bonding surface )
For rigid materials刚性材料: 8 pcs of 400mm x 35mm x end-use thickness
( not exceed 120mm )
For flexible materials Flexible materials : 8 pcs of 460mm x 230mm x end-use thickness (not exceed 120mm). If there is directionality, 4 PCS of the above dimensions in the horizontal and vertical directions
Note:
1)For all rigid materials, and flexible materials which thickness is more than 5mm, Select NF P 92-501, For all rigid materials with thickness greater than 5mm and all hard materials, select NF P92-501 for sample delivery and testing. 2)For flexible materials which thickness is no more than 5mm, Select NF P 92-503 . For soft materials with a thickness not exceeding 5mm , choose NF P92-503 for sample delivery and testing
2) Small parts special cases I0-I4
NF T51-071 ( replace by ISO 4589-2
) or NF G07-128
For plastic:
15pcs of 150mm x 10mm x Thickness deviate less
±10% .
For textile:
15pcs of 150mm x 70mm x end-use thickness
NF C20-455 ( replace by IEC
60695-2-10 )
4 pcs finished product
3) Special cases AD of conductors and cables
NF C32-070
Sample size: 5m
4) Smoke toxicity index classification F0-F5
Light-shielding properties of smoke NF X10-702
Sample size: 20pcs
of 75mm x 75mm x end-use thickness less than 25mm
Smoke toxicity NF X70-100
Sample size: 10pcs finished product
or 500g
NF F 16-101/102 Lead time Test cycle: Regular12 working days